Filter Housings

The element does the filtering. The housing decides if it can.

Four material families, engineered to your duty: Clary-T stainless steel, Plastofilt polypropylene, Polyfilt uPVC, and FRP. Custom designs with no upper size limit, matched to the elements they hold, tested before dispatch.

Photograph to shoot
Clary-T twin-pod stainless housing installed on line, brushed steel, valves visible.

Clary-T Stainless Steel

SS housings for cartridges and bags, from single-element to multi-round banks, including sanitary designs with CIP and SIP readiness for pharma and food. Twin-pod dual-orientation configurations keep continuous processes running through change-outs.

Photograph to shoot
Plastofilt PP housing against a chemical dosing skid backdrop.

Plastofilt Polypropylene

Corrosion-proof PP housings for acids, alkalis, and salt-laden streams where stainless is the wrong answer. Light, chemically inert, economical at scale.

Photograph to shoot
Polyfilt uPVC housing row in a water treatment plant setting.

Polyfilt uPVC

uPVC housings for corrosive liquid duty at lower temperatures and pressures. The cost-effective choice for water treatment chemistry.

Photograph to shoot
FRP housing close-up showing the wound composite surface.

FRP Housings

Fiber-reinforced plastic housings, available off the shelf, for corrosive and coastal environments where metal housings corrode out in seasons.

Stainless Clary-T housings carry general industrial duty, sanitary pharmaceutical, biotech and food processing, sterile vent filtration, lenticular depth-module clarification, plate and frame and sparkler filtration, and high flow cartridge banks. Plastofilt polypropylene and Polyfilt uPVC housings serve corrosive chemistry, dyes and pigments, electronics, water and sewage treatment, and point-of-entry water. ClarySEA-M FRP systems serve seawater desalination and brackish water plants.

One-source advantage: because Gopani manufactures the bags, the cartridges, and the housings, fitment is guaranteed and one engineering team sizes the complete system: housing, elements, and change-out schedule, for your flow and solids load. Line data for every housing is in the tables below.

Clary-T stainless steel housing lines
LineHoldsElement sizesConnection sizesPressureTemperatureNotes
Clary-T IndustrialCartridges: DOE, SOE 222 or 226 flat or fin10 to 40 inch; 60 mm (2.75 inch) to 112 mm (4.5 inch) diameter1/2 to 12 inch7.0 bar65 CClamp closure; knife-edge seal; air vent; SS 304 to Duplex 2507 plus CS, MS, rubber-lined CS and MS
Clary-T SanitaryCartridges: Code 7 or bayonet SOE10 to 40 inch; 60 to 112 mm diameter1/2 to 6 inch7.0 bar65 C3-A sanitary standards (stated), documentation on request; T-style or inline; tri-clover or ASA flanges; fewer welds; 316L
Clary-T VentVent cartridges, Code 75, 10, 20, 30 inch; junior housing on request1/4 to 3 inch-1.0 to 7.0 bar-25 to 135 CSS 316L; internal Ra 0.4 micron or better; low hold-up; jacketed or temperature-controlled versions
Clary-T HFHigh flow cartridges, SOE, inside-to-out20, 40, 60 inch; 152.4 mm (6 inch) diameter1 inch vent and drain; 4 to 20 inch inlet and outlet7.0 bar, other on request65 CSingle or multiple elements; matt, mirror or glass bead blasted finish
Clary-T BFFilter bags: PP collar, rubber collar, SS ring, PP ring, snap bandSize #1 to #41/2 to 6 inch and more7.0 bar, other on request65 CSingle or multi-round; knife-edge seal; hydrostatic leak and burst tested
Clary-T LFLenticular depth filter modules (stacked cellulose pads)Half height, 1, 2, 3 or 4 modules; 300 to 400 mm (12 to 16 inch) diameter2 to 4 inch; 1/2 and 1 inch vent and drain7.0 bar65 CAutoclave, steam, hot water or chemical sanitisation; Rathmann bolt or V-band clamp
Clary-T PFPlate and frame filter sheets, enclosedPlates 200, 400, 600 mm square; 13, 25, 40 mm1 to 4 inch7.0 bar, other on request65 CCIP and SIP; automatic plate shifter and temperature control options; screwed or hydraulic closure
Clary-T SparklerVertical filter press with a choice of filter mediaOn enquiryOn enquiryOn enquiryOn enquiryZero hold-up design; wide range of stainless steels

Specifications are preliminary and are confirmed on the order drawing. Higher pressures are offered on request on the lines marked so.

Clary-T materials, finishes and codes
ParameterOptions
Shell materialsSS 304, SS 316, SS 316L, Duplex SS 2205, Duplex SS 2507; CS, MS and rubber-lined CS or MS on Clary-T Industrial
ClampSS 304
O-ringsSilicone, FKM (Viton), EPDM, PTFE, Buna-N; food-contact elastomer grades confirmed per order
Surface finishMatt, mirror, electropolished (optional), glass bead blasted
ConnectionsBSP, NPT, DIN flange, ASA 150# flange, BS-10 Table D, E or F flange, tri-clover
Design codesASME Section VIII Division 1, U-stamp, UM-stamp, PED 97/23/EC with CE marking, good engineering practice, as the application requires; cGMP on Clary-T Vent
Plastofilt, Polyfilt and ClarySEA-M lines
LineMaterialHoldsSizes and connectionsPressureTemperatureFlow
Plastofilt CFVirgin polypropylene; PP vent with SS spring and screw2.5 and 4.5 inch cartridges, DOE or ZeroLeak (4.5 inch)10 and 20 inch; slim 1/2, 3/4, 1 inch BSP(F); jumbo 1 and 1.5 inch8.0 bar at 21 C4 to 70 CUp to 1 m3/hr (10 inch slim) to 8 m3/hr (20 inch jumbo)
Plastofilt BFPolypropyleneFilter bagsOn enquiryOn enquiryOn enquiryOn enquiry
Polyfilt CF (Gen 3)uPVC, SS swing-nut lock2.5 inch cartridges, DOE or SOE 222 fin; 5 or 9 per vessel10 x 5 to 40 x 5 with 2 inch union; 30 x 9 and 40 x 9 with 3 inch union6 bar at 21 C; hydro-test 11 bar4 to 60 CUp to 54 m3/hr
Polyfilt BF (Gen 3)uPVC, SS swing-nut lockOne size #1 or #2 bag, PP collar7 x 16 or 7 x 32 inch; 2 inch ASA 150 flange4.5 bar at 21 C; hydro-test 11 bar4 to 60 COn enquiry
ClarySEA-M FRPFRVE and FRP shell and head, FRP nozzles63 mm OD cartridges up to 50 inch, SOE 222 flat or fin, or high flow1 to 24 inch ASA 150 flanged7 kg/cm2 standard, higher on request70 C50 to 2000 m3/hr

Seals: silicone standard on Polyfilt; silicone, FKM, Buna-N, EPDM on Plastofilt; silicone, EPDM, Buna-N, Viton on ClarySEA-M.

Plastofilt CF flow by size
HousingCartridge diameterFlow up to
10 inch slim2.5 inch1 m3/hr
10 inch jumbo4.5 inch4 m3/hr
20 inch slim2.5 inch2 m3/hr
20 inch jumbo4.5 inch8 m3/hr

Conditions behind the numbers

Pressure ratings are maximum operating pressures at the stated temperature: Plastofilt at 8.0 bar and Polyfilt at 6 bar or 4.5 bar are rated at 21 C, and plastic housings lose pressure capacity as temperature rises. Flows are housing maximums for water; the element inside sets the real limit. Clary-T figures are preliminary and confirmed on the order drawing.

Elements that fit

Cartridge housings take DOE and SOE 222 or 226 elements from 10 to 40 inch, 6 inch high flow elements, lenticular modules and filter sheets. Bag housings take sizes #1 to #4 with PP collar or steel ring. Clary-T BF takes ClaryFil bags; Polyfilt BF takes size #1 and #2 bags with a PP collar.

Which housing material should I choose?

Stainless Clary-T for pressure, heat, sanitary and solvent duty. Plastofilt polypropylene for acids, alkalis and salt-laden streams at up to 70 C. Polyfilt uPVC for corrosive water chemistry, UV and atmospheric exposure at up to 60 C. ClarySEA-M FRP for seawater and brackish water at large flows. Send the chemistry, pressure, temperature and flow and we recommend the family.

Is there a size limit?

No upper limit on Gopani-built housings. Stainless housings can be made in any stainless grade, and ClarySEA-M FRP systems run from 50 to 2000 m3/hr with 1 to 24 inch connections.

Which design codes can a Clary-T housing be built to?

ASME Section VIII Division 1, with U-stamp or UM-stamp; PED 97/23/EC with CE marking; or good engineering practice where no code applies, as the application requires. Clary-T Vent adds cGMP design. Tell us the code your site requires at enquiry, because it sets wall thickness, documentation and inspection.

What is the Mignon Plus housing?

A point-of-use housing for cold water that takes 5 inch M SX DOE cartridges of 50 mm outside diameter.

Can a housing change without stopping the process?

Yes, with a twin-pod dual-orientation Clary-T configuration: one pod stays on line while the other is serviced, so a continuous process keeps running through the change-out.

  • Fluid chemistry, temperature and operating pressure
  • Flow rate and the element type and rating inside
  • Design code and documentation your site requires
  • Connection type and size, and any sanitary or CIP and SIP need
  • Site conditions: indoor or outdoor, coastal, UV exposure

Each Clary-T housing is stated to undergo hydrostatic leak and burst pressure tests before dispatch. Clary-T lines are offered to ASME Section VIII Division 1 with U-stamp or UM-stamp, to PED 97/23/EC with CE marking, or to good engineering practice, as the application requires; Clary-T Vent adds cGMP design and an internal finish of Ra 0.4 micron or better, with documentation to the relevant standard; Clary-T Sanitary is stated as built to 3-A sanitary standards, documentation on request. Polyfilt housings are hydro-tested to 11 bar, and ClarySEA-M FRP systems are offered non-coded or to ASME Section X or BS 4994. Line specifications are marked preliminary and are confirmed on the order drawing.

Corrosive stream eating your housings?

Tell us the chemistry, pressure, and flow. We will recommend the material family and quote a housing engineered for the duty, not a catalog compromise.